The pHe is a measure of the acid strength of a fuel ethanol and is a predictor of the fuel ethanol’s corrosion potential. Low pHe fuel ethanol can cause corrosive wear in fuel injectors and engine cylinders. High pHe fuel ethanol can cause fuel pump plastic parts to fail. ASTM D4806 Requirement: pHe 6.5 – 9.0.